BS EN 60794-3-50:2008 2009
$167.15
Optical fibre cables – Outdoor cables. Family specification for gas pipe cables and subducts for installation by blowing and/or pulling/dragging in gas pipes
Published By | Publication Date | Number of Pages |
BSI | 2009 | 38 |
IEC 60794-3-50:2008(E) is part of the IEC 60794 family specification that covers gas pipe cables and subducts for installation by blowing and/or pulling/dragging in high pressure gas pipes (400 mbar to 4 bar). Systems built with components covered by this standard are subject to the requirements of sectional specification IEC 60794-3. This standard is to be used in conjunction with IEC 60794-1-1 and IEC 60794-1-2, and IEC 60794-3.
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references |
12 | 3 Symbols and abbreviations |
13 | 4 Family specification for gas pipe cables and subducts for installation by blowing and/or pulling/dragging in gas pipes (blank detail specification and minimum requirements) 4.1 Construction |
14 | 4.2 Optical fibres Tables Table 1 – Single-mode dispersion unshifted (B1.1) optical fibre Table 2 – Single-mode dispersion shifted (B2) optical fibre |
15 | Table 3 – Single-mode non-zero dispersion (B4) optical fibre Table 4 – Single-mode (B6) optical fibre |
16 | 4.3 High pressure gas pipe cable constructions Table 5 – Characteristics – Cable for installation within subducts |
17 | Table 6 – Characteristics – Cable for direct installation within the high pressure gas pipe |
18 | 4.4 Installation and operating conditions Table 7 – Characteristics – Subduct construction Table 8 – Tests applicable to cables/cable elements |
19 | 4.5 Mechanical and environmental tests Table 9 – Tests applicable to subducts |
21 | Table 10 – Tests applicable for OF cables within subducts |
25 | Table 11 – Tests applicable to direct installed OF cables |
29 | Annex A (informative) Blank detail specification Table A.1 – Cables for subduct installation into the gas pipe |
30 | Table A.2 – Cables for direct installation into the gas pipe |
31 | Table A.3 – Subduct description |
32 | Annex B (informative) OF cables for high pressure gas pipes Table B.1 – OF cables for high pressure gas pipes |
33 | Annex C (informative) Examples of subducts and high pressure gas pipe cables Figures Figure C.1 – Example of constructions of cables for installation in subducts within gas pipes |
34 | Figure C.2 – Example of constructions of cables for direct installation into high pressure gas pipes |
35 | Annex D (informative) Example for installation schemes of cables in high pressure gas pipes (fibre-in-gas) Figure D.1 – Picture of an I/O-port Figure D.2 – Schematic drawing of Figure D.1: installation of OF cable within the gas pipe |
36 | Figure D.3 – Schematic drawing of the installation of I/O-ports on high pressure PE gas pipes |